Guidelines for Clinical Management of Laser-Etched (Laser-Lok) Abutments in Two Different Clinical Scenarios: A Preclinical Laboratory Soft Tissue Assessment Study
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 36 , Issue 3
May/June 2016

Pages 339–345


Guidelines for Clinical Management of Laser-Etched (Laser-Lok) Abutments in Two Different Clinical Scenarios: A Preclinical Laboratory Soft Tissue Assessment Study

Rodrigo Neiva, DDS, MS/Nick Tovar, PhD/Ryo Jimbo, DDS, PhD/Luiz F. Gil, DDS, MS/Paula Goldberg, BS/Joao P.M. Barbosa, DDS/Thomas Lilin, DVM/Paulo G. Coelho, DDS, PhD


PMID: 27100803
DOI: 10.11607/prd.2773

One-stage implants were placed in the mandibles of eight beagle dogs with laser-etched (LL) and machined abutments. After 4 weeks, half of the LL abutments were disconnected and reconnected after 10 minutes of saline storage, and the other half were replaced with a new LL abutment (impression simulation) with or without sulcus de-epithelialization. After abutment change, systems remained in vivo for 3 weeks. Results showed that LL abutments can be reconnected and that sulcus scoring prior to LL placement of one-stage implants receiving machined abutments may be beneficial.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help